Stranded Corra/Clad

Coleman Cable - CCI

SKU / Product InfoQuantity
92202
12/2
92203
12/3
92204
12/4
92402
14/2

Quick Overview

    Features & Applications:-
    • Installs fast & easy to lower labor costs in place of conduit and wire
    • Provides superior grounding
    • Flexi-Rib™ design is watertight, bends and stays and can be shaped to tight angles
    • Lightweight aluminum armor means Corra/Clad weighs less than steel armored cable
    • Conductors are soft drawn annealed copper (solid or stranded). Insulation on 18 and 16 AWG is UL Type TFN or TFFN: on 14 AWG and larger, it is UL Type THWN
    • Conductors are cabled with fillers and with an overall seamless corrugated continuous aluminum sheath
    • Type MC Cable can be furnished with a PVC jacket over the sheath for use in corrosive environments or direct burial.
    • Services, feeders and branch circuit
    • Power, lighting, control and signal circuits
    • Indoors, exposed or concealed
    • Direct buried or in concrete encasement (with PVC jacket)
    • As aerial cable on a messenger (with PVC jacket)
    • In cable trays or as open runs
    • Under raised floors, and above suspended ceilings
    • Outdoors or in wet locations (with PVC jacket)
    • Plenums and any air handling passageway
    • Hazardous (classified) environments
    • Health care facilities – outer jacket is an approved grounding means and employs a continuous gas/vapor tight aluminum sheath
    • Remote-Control Signaling, Power-Limited Circuits, Fire Alarm Systems – Fire/Clad®
Interested in this item or want more information?

Hours:

Phone: 877-727-0767

Email:

Can't find what you want? Give us a call and we can help you find it.

Details


Construction Parameters :-

Electrical Properties :-

Conductor 12 AWG Bare Copper
Stranding 19/.0185"
Insulation MaterialPVC/Nylon
Insulation Thickness0.021'' Nom.
Insulated Conductor Diameter0.131'' Nom.
Number of Conductors2
Lay Length3.75'' Nom.
FillerDry Jute
Separator/WrapClear Mylar
Armor MaterialCorrugated Aluminum
Armor Thickness0.021'' Nom.
Overall Cable Diameter0.555'' Nom.
Approximate Cable Weight94.7 Lbs/1M' Nom.
Flame RatingMeets 2 hour through-penetration fire stop requirements.
Temperature Rating-20°C to 90°C
Operating Voltage600 V RMS Max.
Capacitance Between Conductors @ 1 KHz41 pF/ft Nom.
Ampacity per NEC Table 310-1630.00 amps per conductor (Assume 2 current carrying conds.)
DC Resistance per Conductor @ 20°C1.6 Ohms/1M' Nom.